Data
Sheet |
 |
|
Type: |
Open pool |
Power: |
500 kW thermal power |
Average thermal flux at irradiation position: |
5x1012 n/(cm2sec) |
Use: |
Radioisotope production (small lab scale)
Research and Training
Neutron Activation Analysis
Test bench for INVAP projects |
|
|
|
Fuel: |
Enriched Uranium |
Fuel element: |
Plate-type lad in Aluminum |
Coolant: |
Light water (forced downward flow) |
Moderator: |
Light water |
Reflector: |
Graphite - light water |
Control: |
4 absorbing rods in Ag-In-Cd |
Core configuration: |
Variable |
|
|
|
Type: |
Centrifugal pump |
Heat exchanger: |
Plate-type |
|
|
|
Type: |
Cooling tower – centrifugal pump |
|
|
|
Type: |
Mixed bed ion exchange column |
Quantity: |
1 column, 1 filter |
Conductivity at outlet: |
Less than 2 µS/cm |
|
|
|
Diameter: |
2.4 m |
Height: |
9.5 m |
Material: |
Stainless steel |
|
|
|
Section: |
1 x 1.5 m |
Height: |
4 m |
Material: |
Stainless steel |
|
|
| Shielding for Reactor
Taank and Auxiliary Pool |
Axial: |
Light water |
Radial: |
Light water – reinforced heavy concrete |
Irradiation Facilities
| Horizontal Channels
for Neutron-Beam |
|
Type: |
1 with graphite, 1 without graphite |
Location: |
Core grid |
|
|
|
Application: |
Lodging of pneumatic loop terminal.
Handling of irradiated material. |
Quantity: |
1 |
|
|
| Laboratory for Neutron-Activation
Analysis |
|
Equipment |
Irradiation head
Loading and receiving station
Drive system
Pneumatic transport/transfer system |
|
|
| Management of Fuel
Elements (FE) |
|
Irradiated FE: |
Deposited in auxiliary pool |
Storage capacity for spent FE: |
For the reactor life-span |
Instrumentation
|
Start-up: |
Three fission counters |
Power: |
Four ionization chambers |
Main control room (Facing reactor pool): |
Main control desk
Safety officer desk
Shift supervisor desk
Redundant and diversified safety |
|
|
| Radiological Protection
Instrumentation |
|
Equipment: |
Fixed monitors for area activity
Various types of portable monitors |
|
|
| Reactor Building Ventilation
System |
| Type: |
Confinement
with dynamic underpressure
Hermetic isolation valves for emergency. conditions.
Underpressure 10mm of H2O. |
Filters: |
Absolute exhaust filters
for normal conditions.
Absolute and carbon-activated filters for emergency conditions.
Absolute and carbon-activated for recirculation under emergency
conditions. |
|
|
| General Servises and
Facilities |
Clean and dry compressed air |
Fire detection |
Manual and automatic fire extinguishing
system |
| Stand-by power system for
illumination and UPS |
Emergency power illumination system |
Closed TV circuit |
Internal telephone network |
Loudspeaker system |
Bridge crane, 5 ton, with auxiliary stainless
steel hook (1 ton) |
|
 |
Copyright © 2000-2003 INVAP All Rights reserved
|
 |